1.
J. vasc. bras ; 21: e20210178, 2022. graf
Article in Portuguese | LILACS | ID: biblio-1375800

ABSTRACT

Resumo Pacientes portadores de doença arterial obstrutiva periférica com isquemia crítica do membro associada a infecção de prótese vascular apresentam elevadas taxas morbimortalidade e alto risco de perda do membro. Apresentamos o caso de um paciente masculino de 76 anos com isquemia crítica do membro inferior esquerdo associada a infecção de prótese vascular femoropoplítea. Utilizamos abordagem híbrida para o tratamento com acesso cirúrgico das regiões inguinais e poplíteas, sendo a prótese vascular utilizada como acesso endovascular para recanalização direta da artéria femoral superficial devido a obstrução longa e extensa calcificação, que impediram as tentativas iniciais de tratamento endovascular. Após a recanalização endovascular, a prótese infectada foi retirada. O avanço das técnicas e materiais endovasculares em associação com a cirurgia aberta permitem novas soluções para pacientes quando os procedimentos habituais falham.


Abstract Patients with severe arterial obstructive disease and critical limb ischemia associated with vascular graft infection have elevated morbidity and mortality rates and are at high risk of limb loss. We present the case of a 76-year-old male patient with left lower limb critical ischemia and a femoropopliteal vascular graft infection. We used a hybrid treatment approach with an open surgical approach to the inguinal and popliteal regions and used the vascular prosthesis as endovascular access for direct recanalization of the superficial femoral artery, because the long occlusion and extensive calcification had frustrated initial attempts at endovascular treatment. After endovascular recanalization, the infected graft was removed. Used in conjunction with open surgery, advances in endovascular techniques and materials offer new solutions for patients when usual procedures fail.


Subject(s)
Humans , Aged , Prosthesis-Related Infections/surgery , Limb Salvage/methods , Blood Vessel Prosthesis/adverse effects , Endovascular Procedures/methods , Chronic Limb-Threatening Ischemia/surgery
3.
Rev. bras. cir. cardiovasc ; 36(6): 817-821, Nov.-Dec. 2021. tab, graf
Article in English | LILACS | ID: biblio-1351676

ABSTRACT

Abstract The coarctation of the aorta is a relatively highly prevalent congenital heart disease and may be diagnosed as an underline cause of hypertension in adolescents and adults. The gold standard treatment for coarctation of the aorta in these patients is being replaced - from open surgery to endovascular therapy. Some prostheses have been developed to treat the coarctation with less acute and chronic complications. The Dominus® Coarctation Aorta (Braile Biomédica) is the first self-expandable prosthesis created specifically to treat coarctation of the aorta, reducing possible acute complications, like aortic rupture or aortic dissection. Here, we discuss the step-by-step method for using this prosthesis.


Subject(s)
Humans , Adolescent , Adult , Aortic Coarctation/surgery , Aortic Coarctation/complications , Aortic Coarctation/diagnostic imaging , Aortic Dissection/complications , Aorta/surgery , Blood Vessel Prosthesis/adverse effects , Stents/adverse effects , Treatment Outcome
4.
Rev. cir. (Impr.) ; 73(5): 581-586, oct. 2021. tab, ilus
Article in Spanish | LILACS | ID: biblio-1388882

ABSTRACT

Resumen Introducción: La terapia endovascular ha demostrado ser una buena alternativa de tratamiento en las enfermedades arteriales y venosas. Asimismo, en trauma vascular periférico constituye una excelente opción, especialmente en sitios anatómicos difíciles de acceder y con lesiones complejas como seudoaneurismas, fístulas arteriovenosas (FAV) o la combinación de ambos, con numerosas ventajas. Objetivo: Evaluar los resultados del tratamiento endovascular en trauma vascular penetrante por agresiones y iatrogenias. Materiales y Método: Revisión retrospectiva de todos los pacientes con trauma vascular periférico sometidos a terapia endovascular. Resultados: Entre abril de 2011 y mayo de 2020 se trataron 30 pacientes, 28 hombres y 2 mujeres. Con edades fluctuantes entre 17 y 84 años. La causa del trauma fue 20 penetrantes y 10 iatrogenias. Los vasos afectados fueron arteria femoral superficial 6, femoral profunda 2, subclavia 9, axilar 1, poplítea 4, ilíacas 1, peronea 1, tibial anterior 5, tronco venoso braquiocefálico 1. Diecisiete pacientes fueron tratados con endoprótesis, 9 con embolización y 4 con cierre percutáneo en relación con catéteres arteriales en subclavia. No hubo mortalidad, pero dos pacientes requirieron reparación abierta: un seudoaneurisma poplíteo gigante y un seudoaneurisma de tibial anterior, en ambos se constató sección completa de ambas arterias. El seguimiento clínico ha sido entre 30 días y 3 años. Conclusiones: En esta serie de casos, la terapia endovascular en lesiones de trauma vascular periférico ofrece excelentes resultados con baja morbimortalidad y permeabilidad aceptable a corto y mediano plazo.


Introduction: Endovascular therapy has proven to be a good treatment alternative in arterial and venous diseases. Likewise, in peripheral vascular trauma it is an excellent option, especially in anatomical sites that are difficult to access and with complex lesions such as pseudoaneurysms, arteriovenous fistulas (AVFs) or the combination of both, with numerous advantages. Aim: To evaluate the results of endovascular treatment in trauma Penetrating vascular injury and iatrogenesis. Materials and Method: Retrospective review of all patients with peripheral vascular trauma undergoing endovascular therapy. Results: Between April 2011 and May 2020, 30 patients were treated, 28 men and 2 women. With fluctuating ages between 17 and 84 years. The cause of the trauma was 20 penetrating and 10 iatrogenic. The affected vessels were superficial femoral artery 6, deep femoral 2, subclavian 9, axillary 1, popliteal 4, iliac 1, peroneal 1, anterior tibial 5, brachiocephalic venous trunk 1. Seventeen patients were treated with endoprosthesis, 9 with embolization and 4 with percutaneous closure in relation to arterial catheters in the subclavian. There was no mortality but two patients required open repair: a giant popliteal pseudoaneurysm and an anterior tibial pseudoaneurysm in which both sections of both arteries were found to be complete. Clinical follow-up was between 30 days and 3 years. Conclusión: In this serie, endovascular therapy in peripheral vascular trauma lesions offers excellent results with low morbidity and mortality and acceptable patency in the short and medium term.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Aged, 80 and over , Arteries/injuries , Wounds, Nonpenetrating/therapy , Wounds, Penetrating/therapy , Endovascular Procedures/methods , Wounds, Nonpenetrating/diagnosis , Wounds, Penetrating/diagnosis , Blood Vessel Prosthesis/statistics & numerical data , Retrospective Studies
5.
Rev. bras. cir. cardiovasc ; 36(4): 561-564, July-Aug. 2021. tab, graf
Article in English | LILACS | ID: biblio-1347157

ABSTRACT

Abstract Patients with complex Stanford type B aortic dissection are very difficult to treat. Many methods have been proposed so far in the treatment of these patients, and the emergence of hybrid techniques has made the treatment easier. In this article, we shared the extra-anatomical bypass (aorto-celiac-mesenteric bypass) + thoracic endovascular aortic repair + cholecystectomy operation technique applied to a patient with complex type B aortic dissection.


Subject(s)
Humans , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Blood Vessel Prosthesis , Cholecystectomy , Retrospective Studies , Dissection
6.
Rev. bras. cir. cardiovasc ; 36(3): 365-371, May-June 2021. tab, graf
Article in English | LILACS | ID: biblio-1288238

ABSTRACT

Abstract Objective: The positional relationship between the three branches of the aortic arch was determined in normal people. This study provides data to support the customization of aortic arch stents and simplifies intraluminal treatment. Methods: From January 2019 to August 2019, 120 patients who met the inclusion criteria were examined by CT angiography. The ratio of the distance from the midpoint of the three-branch opening onto the anterior wall to the cross-sectional diameter of the aortic arch was calculated. The positional relationship among the three-branch openings was obtained and the data were analyzed statistically. Results: The three-branch openings were not in a straight line. The positional relationship among the three-branch openings was divided into four types, which were not statistically different between sex and age (P>0.05). Conclusion: By measuring the opening position of the three aortic branches, the positional relationship among the three branches was defined to provide a theoretical basis for the design of intraluminal stents and simplified intracavity thoracic endovascular aortic repair (TEVAR) technology.


Subject(s)
Humans , Aortic Aneurysm, Thoracic/surgery , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Aorta, Thoracic/surgery , Aorta, Thoracic/diagnostic imaging , Prosthesis Design , Blood Vessel Prosthesis , Stents , Retrospective Studies , Treatment Outcome
7.
CorSalud ; 13(1): 104-108, 2021. graf
Article in Spanish | LILACS | ID: biblio-1345927

ABSTRACT

RESUMEN El pseudoaneurisma es aquel hematoma pulsátil y encapsulado producido tras la rotura de todas las túnicas del vaso y contenido por tejidos vecinos circundantes. Es considerado una complicación tardía en la cirugía protésica aorto-ilíaca. Se presenta un paciente de 72 años al que se le realizó un baipás aorto-bifemoral 13 años atrás, y que posteriormente se le diagnosticó un pseudoaneurisma para-anastomótico que se dejó evolucionar por presentar varias comorbilidades asociadas. Transcurridos 2 años fue necesario realizarle una intervención quirúrgica por presentar crecimiento excesivo de la tumefacción y complicación isquémica con necrosis cutánea. La aparición de un pseudoaneurisma está relacionada con el sexo, el material protésico y con el tiempo que transcurre desde la cirugía. El seguimiento ultrasonográfico durante el postoperatorio es primordial para identificar tempranamente esta complicación.


ABSTRACT Pseudoaneurysm is that pulsatile and encapsulated hematoma produced after the rupture of all vessel layers and contained by surrounding neighboring tissues. It is considered a late complication in aorto-iliac prosthetic surgery. We present a 72-year-old patient who underwent an aorto-bifemoral bypass grafting 13 years ago, and who was subsequently diagnosed with a para-anastomotic pseudoaneurysm that was allowed to evolve due to presenting several associated comorbidities. After two years, it was necessary to perform a surgical intervention due to the excessive growth of the swelling, and ischemic complication with skin necrosis. The appearance of a pseudoaneurysm is related to sex, prosthetic material as well as the time that elapses since the surgery. Ultrasound follow-up during the postoperative period is essential for an early identification of this complication.


Subject(s)
General Surgery , Blood Vessel Prosthesis , Aneurysm, False , Femoral Artery , Vascular Grafting
8.
Clinics ; 76: e2812, 2021. tab, graf
Article in English | LILACS | ID: biblio-1249575

ABSTRACT

OBJECTIVES: We sought to analyze the hemodynamic effects of the multilayer flow-modulated stent (MFMS) in Thoracoabdominal aortic aneurysms (TAAAs). METHODS: The hemodynamic effects of MFMS were analyzed in aortic thoracoabdominal aneurysms in experimental swine models. We randomly assigned 18 pigs to the stent or control groups and underwent the creation of an artificial bovine pericardium transrenal aneurysm. In the stent group, an MFMS (Cardiatis, Isnes, Belgium) was immediately implanted. After 4 weeks, we evaluated aneurysm sac thrombosis and renal branch patency by angiography, duplex scan, and morphological analysis. RESULTS: All the renal arteries remained patent after re-evaluation in both groups. Aneurysmal sac thrombosis was absent in the control group, whereas in the stent group it was present in 66.7% of aneurysmal sacs (p=0.061). The mean final aneurysm sac diameter was significantly lower in the stent group (mean estimated reduction, 6.90 mm; p=0.021). The proximal neck diameter decreased significantly in the stent group (mean difference, 2.51 mm; p=0.022) and grew significantly in the control group (mean difference, 3.02 mm; p=0.007). The distal neck diameter increased significantly in the control group (mean difference, 3.24 mm; p=0.017). There were no significant findings regarding distal neck measurements in the stent group. CONCLUSION: The MFMSs remained patent and did not obstruct the renal arteries within 4 weeks. In the stent group, the device was also associated with a significant decrease in aneurysmal sac diameter and a large proportion (albeit non-significant) of aneurysmal sac thrombosis.


Subject(s)
Animals , Aortic Aneurysm , Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Prosthesis Design , Renal Artery/surgery , Renal Artery/diagnostic imaging , Swine , Blood Vessel Prosthesis , Cattle , Stents , Treatment Outcome , Models, Theoretical
9.
Clinics ; 76: e2890, 2021. tab
Article in English | LILACS | ID: biblio-1286064

ABSTRACT

OBJECTIVES: In Brazil, descending thoracic aorta disease, including aneurysms and dissections, is managed preferentially by endovascular treatment, owing to its feasibility and good results. In this study, we analyzed endovascular treatment of isolated descending thoracic aortic disease cases in the Brazilian public health system over a 12-year period. METHODS: Public data from procedures performed from 2008 to 2019 were extracted using web scraping techniques to assess procedure type frequency (elective or urgency), mortality, and governmental costs. RESULTS: A total of 5,595 procedures were analyzed, the vast majority of which were urgent procedures (61.82% vs. 38.18%). In-hospital mortality was lower for elective than for urgent surgeries (4.96 vs.10.32% p=0.008). An average of R$16,845.86 and R$20,012.04 was paid per elective and emergency procedure, respectively, with no statistical difference (p=0.095). CONCLUSION: Elective procedures were associated with lower mortality than urgent procedures. There was no statistically significant difference between elective and urgent procedures regarding costs.


Subject(s)
Humans , Aortic Aneurysm, Thoracic/surgery , Aortic Aneurysm, Thoracic/epidemiology , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Aorta, Thoracic/surgery , Brazil/epidemiology , Blood Vessel Prosthesis , Stents , Public Health , Treatment Outcome
10.
Rev. Col. Bras. Cir ; 48: e20202587, 2021. graf
Article in English | LILACS | ID: biblio-1155357

ABSTRACT

ABSTRACT Objectives: the aim of this study was to compare the outcomes of a new silicone vascular prostheses with PTFE vascular prostheses, on a rabbit experimental model. Methods: forty rabbits underwent infra-renal aorta replacement with 4 mm diameter prostheses, twenty animals with PDMS and twenty animals with PTFE (control group). Retrograde aortic angiography was performed to assess patency. Histological graft samples were examined by electron microscopy to evaluate prostheses endothelialization. Results: patency rates were 100% for both grafts after 30 days; after 60 days, patency rate for PDMS was 92.3% (±7.4), and 73,8% (±13.1) at 90 days. PTFE grafts had patency rates of 87.5% (±11.7) at 60 and 90 days. No statistically significant difference was found in between groups for patency rates (p=0.62). Postoperative complications (death, paraplegia) rates (p=0.526) and aortic clamping times (p=0.299) were comparable in both groups. No statistically significant difference for stenosis was found on angiographical analysis between groups (p=0.650). Electron microscopy revealed limited anastomotic endothelial ingrowth in both prostheses. Conclusion: in this experimental model, PDMS and PTFE vascular prostheses had comparable outcomes and PDMS prosthesis could be used as a vascular graft.


RESUMO Objetivo: analisar novo tubo de silicone como material para prótese vascular e compará-lo a prótese de PTFE, em modelo experimental com coelhos. Métodos: quarenta coelhos foram submetidos a interposição, na aorta infrarrenal, de próteses de 4mm de diâmetro, sendo 20 animais com PDMS e 20 com PTFE (grupo controle). Foi realizada arteriografia retrógrada da aorta para avaliar a patência das próteses. Para avaliar a endotelização das próteses foi realizada microscopia eletrônica de maneira amostral pareada. Resultados: a patência em 30 dias foi de 100% para as duas próteses. Aos 60 dias, a taxa de patência do PDMS foi de 92,3% (± 7,4), e de 73,8% (±13,1) em 90 dias; as próteses de PTFE tiveram taxas de patência de 87,5% (± 11,7) aos 60 e 90 dias. Não foi observada diferença significativa entre as taxas de patência dos grupos (p=0,62). Não foi observada diferença entre os grupos quanto à evolução com complicações pós-operatórias (p=0,526) e quanto ao tempo de clampeamento da aorta (p=0,299). Não houve diferença significativa entre os grupos quanto ao grau de estenose das próteses (p=0,650) à avaliação angiográfica. A microscopia eletrônica mostrou crescimento endotelial limitado às regiões próximas às anastomoses nos dois tipos de próteses. Conclusões: o PDMS mostrou-se passível de utilização como prótese vascular, com resultados comparáveis aos do PTFE no modelo utilizado.


Subject(s)
Animals , Aorta/surgery , Polytetrafluoroethylene/therapeutic use , Silicones/therapeutic use , Blood Vessel Prosthesis , Polyesters , Rabbits
11.
Acta Academiae Medicinae Sinicae ; (6): 917-921, 2021.
Article in Chinese | WPRIM | ID: wpr-921560

ABSTRACT

Objective To explore the cause and the treatment strategies of iliac limb occlusion after endovascular abdominal aortic aneurysm repair(EVAR). Methods The patients receiving EVAR in PUMC Hospital from January 2015 to December 2020 were retrospectively analyzed.Sixteen(2.7%)cases of iliac limb occlusion were identified,among which 6,9,and 1 cases underwent surgical bypass,endovascular or hybrid procedure,and conservative treatment,respectively. Results Fifteen cases were successfully treated.During the 10.6-month follow-up,2 cases receiving hybrid treatment underwent femoral-femoral bypass due to re-occlusion of the iliac limb. Conclusions Iliac limb occlusion mostly occurs in the acute phase after EVAR,and endovascular or hybrid treatment can be the first choice for iliac limb occlusion.It is suggested to focus on the risk factors for prevention.


Subject(s)
Humans , Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/adverse effects , Endovascular Procedures , Iliac Artery/surgery , Retrospective Studies , Risk Factors , Stents , Treatment Outcome
12.
Rev. bras. cir. cardiovasc ; 35(6): 934-941, Nov.-Dec. 2020. tab, graf
Article in English | LILACS, SES-SP | ID: biblio-1143992

ABSTRACT

Abstract Introduction: The aim of this study is to compare postoperative outcomes and follow-up of two different modifications facilitating surgical technique of frozen elephant trunk (FET) procedure for complex thoracic aortic diseases - zone 0 (fixation with total arch debranching) and zone 3 (fixation with islet-shape arch repair). Methods: From May 2012 to December 2018, data were collected from 139 patients who had been treated with FET procedure for complex thoracic aortic diseases. According to Ishimaru arch map, patients with proximal anastomotic site of hybrid graft at zone 0 and zone 3 were grouped as Group A (n=58, 41.7%) and Group B (n=81, 58.3%), respectively. Mean age of study population was 54.7±11.4 years, and 111 patients were male (79.9%). Results: In-hospital mortality was observed in 20 (14.4%) patients (n=12, acute type A aortic dissection, and n=4, previous aortic dissection surgery). There was no significant difference between both groups in terms of in-hospital mortality. Four patients from Group A and three patients from Group B had permanent neurological deficit (P=0.32). Three patients from both groups had transient spinal cord ischemia (P=0.334). Although mean total perfusion time was longer in Group A, duration of visceral ischemia, when compared with Group B, was shorter (P<0.001). Five-year survival rate was 82.8% in Group A and 81.5% in Group B (P=0.876). Conclusion: FET procedure is a feasible repair technique in the treatment of complex aortic diseases, providing satisfactory early results. Because of its advantageous aspects, zone 0 fixation with debranching is the preferred technique in our clinic.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Aortic Aneurysm, Thoracic/surgery , Aortic Aneurysm, Thoracic/diagnostic imaging , Blood Vessel Prosthesis Implantation , Aortic Dissection/surgery , Aortic Dissection/diagnostic imaging , Aorta, Thoracic/surgery , Blood Vessel Prosthesis , Stents , Retrospective Studies , Treatment Outcome
13.
Rev. bras. cir. cardiovasc ; 35(5): 781-788, Sept.-Oct. 2020. tab, graf
Article in English | LILACS, SES-SP | ID: biblio-1137328

ABSTRACT

Abstract We performed a review of the literature (until August 01, 2019) on the occasion of the first transcaval approach for transcatheter aortic valve implantation in our hospital. This review focuses mainly on the indications of this alternative access route to the aorta. It may be useful for vascular surgeons in selected cases, such as the treatment of endoleaks after endovascular aneurysm repair and thoracic endovascular aneurysm repair. We describe historical aspects of transcaval access to the aorta, experimental studies, available case series and outcomes. Finally, we summarize the most significant technical aspects of this little-known access.


Subject(s)
Humans , Male , Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Surgeons , Aorta, Abdominal/surgery , Blood Vessel Prosthesis , Stents , Treatment Outcome
14.
Rev. bras. cir. cardiovasc ; 35(4): 427-436, July-Aug. 2020. tab, graf
Article in English | LILACS, SES-SP | ID: biblio-1137284

ABSTRACT

Abstract Objective: To systematically review the rate of morbidity and mortality associated with the use of E-vita hybrid stent graft and ThoraflexTM in patients undergoing complex aortic surgery. Methods: A comprehensive search was undertaken among the four major databases to identify published data about E-vita or Thoraflex™ in patients undergoing repair of thoracic aortic aneurysms. Results: In total, 28 papers were included in the study, encompassing a total of 2,161 patients (1,919 E-vita and 242 Thoraflex™). Patients undergoing surgery with E-vita or Thoraflex™ were of similar age and sex. The number of patients undergoing non-elective repair with Thoraflex™ was higher than with E-vita (35.2% vs. 28.7%, respectively). Cardiopulmonary bypass time was associated with increasing mortality in E-vita patients, however a meta-analysis of proportions showed higher 30-day mortality, permanent neurological deficit, and one-year mortality for Thoraflex™ patients. Direct statistical comparisons between E-vita and Thoraflex™ was not possible due to heterogeneity of studies. Conclusion: Although there are limited studies available, the available data suggests that mortality and morbidity are lower for the E-vita device in thoracic aortic aneurysm surgery than for Thoraflex™. Long-term data of comparative studies do not yet exist to assess viability of these procedures.


Subject(s)
Humans , Aortic Aneurysm, Thoracic/surgery , Blood Vessel Prosthesis Implantation , Aorta, Thoracic/surgery , Blood Vessel Prosthesis , Stents , Treatment Outcome
15.
Rev. gastroenterol. Perú ; 40(3): 267-269, Jul-Sep 2020. graf
Article in Spanish | LILACS | ID: biblio-1144674

ABSTRACT

RESUMEN La formación de una fístula entre arterias de gran calibre y el tubo digestivo es una complicación infrecuente de la cirugía reconstructiva de los grandes vasos sanguíneos secundario al uso de prótesis vasculares, los cuales se manifiestan con hemorragias masivas con elevada mortalidad. Presentamos dos casos de fístula aorto-entérico y de fístula carotideo-esofágico que comparten características comunes como la manifestación clínica de hemorragia digestiva masiva y mortal en pacientes con antecedentes de colocación de prótesis vasculares.


ABSTRACT The formation of a fistula between large caliber arteries and the digestive tract is an uncommon complication of reconstructive surgery of the large vessels secondary to the use of vascular prostheses, which manifest themselves with massive hemorrhages with high mortality. We report two cases of aorto-enteric fistula and carotid-esophageal fistula that share common characteristics such as the clinical manifestation of massive and fatal gastrointestinal bleeding in patients with a history of vascular prosthesis placement.


Subject(s)
Aged , Humans , Male , Middle Aged , Aortic Diseases/etiology , Carotid Artery Diseases/etiology , Vascular Fistula/etiology , Esophageal Fistula/etiology , Postoperative Complications/etiology , Severity of Illness Index , Blood Vessel Prosthesis/adverse effects , Gastrointestinal Hemorrhage
16.
J. bras. nefrol ; 42(1): 38-46, Jan.-Mar. 2020. tab, graf
Article in English, Portuguese | LILACS | ID: biblio-1098336

ABSTRACT

ABSTRACT Introduction: The vascular access cannulation technique varies among clinics, and guidelines on vascular access give little importance to cannulation techniques. The objective of this study was to evaluate the cannulation technique and to determine which factors are associated with each detail of the technique. Material and methods: The vascular access cannulation was evaluated in 260 patients undergoing hemodialysis. The type and anatomical location of the vascular access, the cannulation technique, direction, gauge, and distance between needles, besides bevel direction and needle rotation were registered. Results: The arteriovenous fistula was the most frequent vascular access (88%), the most used cannulation technique was area (100%), the needle direction was anterograde in most cases (79.5%), and the mean distance between the tips of needles was 7.57±4.43 cm. For arteriovenous grafts, the proximal anatomical location (brachial artery) and cannulation with 16G needles in anterograde position were more predominant. For arteriovenous fistulas, the distal anatomical location (radial artery) and cannulation through 15G needles were more common. Cannulation of vascular access in retrograde direction was associated with a greater distance between needles (13.2 ± 4.4 vs 6.1 ± 3 cm, p < 0.001). Kt/V was higher when the distance between needles was higher than 5 cm (1.61 ± 0.3 vs. 1.47 ± 0.28, p < 0.01). Conclusions: The vascular access cannulation technique depends on the vascular access characteristics and expertise of cannulators. Clinical trials are required for the formulation of guidelines for vascular access cannulation.


RESUMO Introdução: A técnica de canulação do acesso vascular varia entre instituições de saúde, e as diretrizes sobre o acesso vascular dão pouca importância às técnicas de canulação. O objetivo deste estudo foi avaliar a técnica de canulação e determinar quais fatores estão associados a cada detalhe da técnica. Material e métodos: A canulação do acesso vascular foi avaliada em 260 pacientes em hemodiálise. Foram registrados o tipo e localização anatômica do acesso vascular, a técnica de canulação, a direção, a bitola e a distância entre as agulhas, além da direção do bisel e da rotação da agulha. Resultados: A fístula arteriovenosa foi o acesso vascular mais frequente (88%), a técnica de canulação mais utilizada foi a área (100%), a direção da agulha foi anterógrada na maioria dos casos (79,5%) e a distância média entre as pontas das agulhas foi de 7,57 ± 4,43 cm. Para enxertos arteriovenosos, a localização anatômica proximal (artéria braquial) e a canulação com agulhas 16G em posição anterógrada foram mais predominantes. Para as fístulas arteriovenosas, a localização anatômica distal (artéria radial) e a canulação através de agulhas 15G foram mais comuns. A canulação do acesso vascular na direção retrógrada foi associada a uma maior distância entre as agulhas (13,2 ± 4,4 v.s. 6,1 ± 3 cm, p < 0,001). O Kt / V foi maior quando a distância entre as agulhas foi superior a 5 cm (1,61 ± 0,3 vs. 1,47 ± 0,28, p < 0,01). Conclusões: A técnica de canulação do acesso vascular depende das características do acesso vascular e da experiência dos "canuladores". Ensaios clínicos são necessários para a formulação de diretrizes para a canulação do acesso vascular.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Middle Aged , Aged , Aged, 80 and over , Young Adult , Catheterization/instrumentation , Catheterization/methods , Arteriovenous Fistula , Renal Dialysis/methods , Needles , Brazil , Blood Vessel Prosthesis , Risk , Cross-Sectional Studies , Treatment Outcome , Vascular Access Devices
17.
Rev. colomb. cir ; 35(4): 647-658, 2020. tab, fig
Article in Spanish | LILACS | ID: biblio-1147911

ABSTRACT

Introducción. Las malformaciones vasculares son anomalías que están presentes desde el nacimiento, no desaparecen y pueden crecer a lo largo de la vida. Se ha demostrado en estudios retrospectivos que la terminología para clasificar las anomalías vasculares es inexacta en un 69 % de casos, por lo que se hace un diagnostico inadecuado y en un 53 % de casos se brinda al paciente y su familia una información incorrecta del tratamiento y el curso clínico. Métodos. Estudio prospectivo longitudinal, realizado entre 2016 y 2019, donde se incluyeron pacientes con anomalías vasculares, que consultaron a nuestra institución, fueron valorados por el servicio de cirugía vascular, se hizo un plan diagnóstico y manejo integral, vía endovascular, quirúrgica o mixta, de acuerdo con cada caso. Resultados. La malformación más común fue la de tipo venoso, en el 40,3 % de los casos. Se realizó manejo endovascular en el 93,1 % de casos de malformaciones vasculares y quirúrgico en el 6,9 %. La mejoría de los síntomas que motivaron la consulta fue del 100 % para los tumores vasculares y del 70,8 % para las malformaciones. Sin embargo, los resultados son heterogéneos. Discusión. Es necesario realizar un adecuado diagnóstico de las anomalías vasculares, para alcanzar un trata-miento eficaz, con mejoría de los síntomas


Introduction. Vascular malformations are abnormalities that are present from birth, do not disappear and can grow throughout life. It has been shown in retrospective studies that the terminology to classify vascular anomalies is inaccurate in 69% of cases, an inappropriate diagnosis is made and in 53% of cases the patient and their family are given incorrect information on the treatment and the clinical course.Methods. Longitudinal prospective study conducted between 2016 and 2019. Patients with vascular anomalies and consulted to our institution were included. They were evaluated by the vascular surgery service, and a comprehensive diagnosis and management plan was made, including endovascular, surgical or mixed, according to each case. Results. The most common malformation was the venous type in 40.3% of the cases. Endovascular management was performed in 93.1% of cases and surgery in 6.9%. The improvement in the symptoms that led to the con-sultation was 100% for vascular tumors and 70.8% for malformations. However, the results are heterogeneous.Conclusions. It is necessary to obtain an adequate diagnosis of vascular anomalies, to achieve an effective treatment, with improvement of the symptoms


Subject(s)
Humans , Vascular Malformations , Vascular Surgical Procedures , Blood Vessel Prosthesis , Neoplasms, Vascular Tissue
18.
Arq. bras. cardiol ; 113(5): 1002-1005, Nov. 2019. graf
Article in English | LILACS | ID: biblio-1055043

ABSTRACT

Abstract Fistula from left internal mammary artery (LIMA) to pulmonary artery (PA) is rarely encountered in daily practice. In recent years, endovascular therapy options have emerged for the treatment of fistula formations and replaced with surgery. A 53-year-old man admitted to our outpatient clinic with symptoms of typical angina and shortness of breath despite optimal medical therapy. In his relevant history, he had a coronary artery bypass graft (CABG) operation in 2009 in which his LIMA was anastomosed to left anterior descending (LAD) and ramus artery sequentially. Coronary angiography including selective imaging of LIMA demonstrated a fistula formation originating from the proximal portion of the LIMA and draining to PA. After successful closure of fistula with transcatheter coil embolization, the patient was discharged without any complication and symptom. In conclusion, although LIMA to PA fistula is an infrequent clinical condition, it should be considered as a potential cause of persistent angina after CABG operation. Treatment options include conservative medical therapy, surgical ligation and endovascular interventions. The best therapy should be individualised for each patient in respect to patient's symptoms, surgical compatibility and anatomy of fistula.


Resumo A fístula da artéria mamária interna esquerda (AMIE) para a artéria pulmonar (AP) é raramente encontrada na prática diária. Nos últimos anos, opções de terapia endovascular surgiram para o tratamento de formações de fístula e foram substituídas por cirurgia. Um homem de 53 anos de idade, internado em nosso ambulatório com sintomas de angina típica e falta de ar, apesar da terapia clínica ideal. Em seu histórico relevante, ele teve uma cirurgia de revascularização miocárdica (CRM) em 2009, na qual sua AMIE foi anastomosada à descendente anterior esquerda (DAE) e à artéria ramus sequencialmente. A angiografia coronária, incluindo imagens seletivas da AMIE, demonstrou uma formação de fístula proveniente da porção proximal da AMIE e drenando para AP. Após o fechamento bem-sucedido da fístula com embolização transcateter com mola, o paciente recebeu alta sem qualquer complicação e sintoma. Em conclusão, embora fístula entre AMIE e AP seja uma condição clínica pouco frequente, deve ser considerada como uma causa potencial de angina persistente após a operação de revascularização do miocárdio. As opções de tratamento incluem terapia médica conservadora, ligadura cirúrgica e intervenções endovasculares. A melhor terapia deve ser individualizada para cada paciente em relação aos sintomas do paciente, compatibilidade cirúrgica e anatomia da fístula.


Subject(s)
Humans , Male , Middle Aged , Pulmonary Artery , Catheterization, Peripheral/methods , Arterio-Arterial Fistula/therapy , Embolization, Therapeutic/methods , Angina Pectoris/therapy , Mammary Arteries , Postoperative Complications , Blood Vessel Prosthesis , Coronary Artery Bypass/adverse effects , Arterio-Arterial Fistula/complications , Arterio-Arterial Fistula/etiology , Treatment Outcome , Self Expandable Metallic Stents , Angina Pectoris/etiology
19.
Annals of Surgical Treatment and Research ; : 237-249, 2019.
Article in English | WPRIM | ID: wpr-739588

ABSTRACT

PURPOSE: Recent studies have analyzed the short-term clinical outcomes of ndovascular management. However, the long-term outcomes are unknown. This study aimed to investigate clinical outcomes after endovascular management for ruptured pseudoaneurysm in patients after pancreaticoduodenectomy (PD). METHODS: The medical records of 2,783 patients who underwent PD were retrospectively reviewed at a single center. Of 62 patients who received intervention after pseudonaeurysm rupture, 57 patients (91.9%) experienced eventual success of hemostasis. The patients were composed as follows: (embolization only [EMB], n = 30), (stent-graft placement only [STENT], n = 19) and (both embolization and stent-graft placement simultaneously or different times [EMB + STENT], n = 8). Long-term complications were defined as events that occur more than 30 days after the last successful endovascular treatment. RESULTS: Among 57 patients, short-term stent-graft related complications developed in 3 patients (5.3%) and clinical complication developed in 18 patients (31.5%). Nine (15.8%) had long-term stent-graft related complications, which involved partial thrombosis in 5 cases, occlusion in 3 cases and migration in 1 case. Except for 1 death, the remaining 8 cases did not experience clinical complications. The stent graft primary patency rate was 88.9% after 1 month, 84.2% after 1 year, and 63.2% after 2 years. Of 57 patients, 30 days mortality occurred in 8 patients (14.0%). CONCLUSION: After recovery from initial complication, most of patients did not experience fatal clinical complication during long-term follow-up. Endovascular management is an effective and safe management of pseudoaneurysm rupture after PD in terms of long-term safety.


Subject(s)
Humans , Aneurysm, False , Blood Vessel Prosthesis , Embolization, Therapeutic , Follow-Up Studies , Hemostasis , Medical Records , Mortality , Pancreaticoduodenectomy , Retrospective Studies , Rupture , Stents , Thrombosis
20.
Annals of Surgical Treatment and Research ; : 138-145, 2019.
Article in English | WPRIM | ID: wpr-739572

ABSTRACT

PURPOSE: The use of endovascular aneurysm repair (EVAR) for ruptured abdominal aortic aneurysms (r-AAA) is steadily increasing. We report early experiences of EVAR for r-AAA performed in two tertiary referral centers in Korea. METHODS: We retrospectively reviewed r-AAA patients treated by EVAR from May 2013 to December 2017. An EVAR-first strategy for r-AAA was adopted whenever feasible. The demographic information, anatomic characteristics, operative details, postoperative complications with special attention to abdominal compartment syndrome (ACS), and 30-day mortality were collected and analyzed. RESULTS: We identified 13 patients who underwent EVAR for r-AAA. Mean age was 74.2 years and mean AAA size was 74.2 mm. Two patients underwent cardiopulmonary resuscitation at initial presentation. Bifurcated stent grafts were used in 12 out of 13 cases and physician-modified endografts with fenestrated/chimney techniques were performed in 2 cases with short neck. Successful stent graft deployment was achieved in all cases. Three patients were suspected of having ACS and 2 of them underwent laparotomy for decompression. The 30-day mortality was 7.7% (1 of 13), the only mortality being a patient that refused decompressive laparotomy for suspected ACS. CONCLUSION: Despite the small numbers, the outcomes of EVAR for treatment of r-AAA were very promising, even in selected cases with unfavorable anatomy. These outcomes were achieved by a dedicated and well-trained team approach, and by use of high-end angiographic technology. Finally, ACS after EVAR is not uncommon, and requires a high index of suspicion as well as liberal use of decompressive surgery.


Subject(s)
Humans , Aneurysm , Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis , Cardiopulmonary Resuscitation , Decompression , Endovascular Procedures , Intra-Abdominal Hypertension , Korea , Laparotomy , Mortality , Neck , Postoperative Complications , Retrospective Studies , Rupture , Tertiary Care Centers
SELECTION OF CITATIONS